The installation of the water pipe should not leak, and the material of the pipe fittings needs to be selected by the user based on factors such as pressure, installation convenience, and cost, and purchased locally. If the drop is 100 meters, the actual water pressure is 1.0Mpa, and the actual pressure of the pipe should be above 1.0Mpa.
The minimum recommended installation pipe inner diameter in this sample is recommended when the pipeline length is not greater than twice the water head. Because there is a pressure loss when water flows through the pipeline, the thinner the pipe, the faster the water flow rate, the greater the pressure loss, the smaller the net head, and the smaller the power generation of the generator. Therefore, if the pipeline is too long, when selecting the pipeline, try to choose a larger inner diameter of the pipeline. Many customers are concerned that the water intake pipe is too large and insufficient, which is unnecessary. Because the water consumption is mainly determined by the water turbine, the water pipe is only used for water diversion. The adjustment of water volume can be carried out using valves on the inlet pipeline.