EEWSI 600W
ENGELEC
EEWSI 600W
EEWSI 600W Off-grid Integrated Controller&Inverter Data Sheet.pdf
Availability: | |
---|---|
EEWSI 600W Off-grid Integrated Controller&Inverter
Applications
This product can be applied to household off-grid system and power supply for the coastal islands.
Features
Ø Wind&solar hybrid, controller and inverter integrated machine
Ø Industrial frequency isolation. Safe and reasonable
Ø Complete protection functions
Ø Comply with the CE certification
Technical Parameters
Model | WWSI0610-24 |
Wind Turbine Input | |
Rated input power | 600W |
Input voltage range | 0~32V |
Rated input current | 25A |
Brake by hand | Turn on the brake switch,and it will unload completely. Then, it need be recovered by manual operation |
Brake by over current | 25A |
Brake by overvoltage | Refer to "output overvoltage" control |
PV input | |
Rated input power | 180W |
Max. Open circuit voltage | 48V |
Rated input current | 8A |
Charge Parameters | |
Rated battery voltage | 24V |
Output overvoltage point | 29V |
AC Output | |
DC input voltage range | 21.6V~34V |
Undervoltage recovery point | Refer to "rated battery voltage" |
Rated output power | 1000VA |
Rated output voltage | 110/120/220/230/240V |
Rated phase number | Single phase |
Rated output frequency | 50/60±0.5Hz |
THDi | <5% |
Max. conversion efficiency | ≥85% |
Overload protection | 120% rated DC output -1min,150% rated DC output -10s |
General Parameters | |
Display mode | LCD |
Display information | Battery voltage, charge current, brake display, battery overvoltage/undervoltage, overload, load short circuit, and equipment overheat status. |
Isolation mode | Industrial frequency isolation |
Static loss | ≤0.8A |
Protection function | Lightning protection;Wind turbine: manual brake, automatic brake; PV:PV reversed connection protection, reversed charging protection; Battery: battery reversed connection protection, overvoltage protection; Load:overload protection, short circuit protection, overheating protection; and so on. |
Ambient temperature | -20℃~+40℃ |
Humidity | 0~90%, No condensing |
Noise | ≤65db |
Cooling mode | Forced air cooling |
Cover protection class | IP20 |
Product dimension (W*H*D) | 344*165*402 mm |
Product net weight | 15kg |
Note: Part of parameters can be adjusted according to customer’s specific demand. |
EEWSI 600W Off-grid Integrated Controller&Inverter
Applications
This product can be applied to household off-grid system and power supply for the coastal islands.
Features
Ø Wind&solar hybrid, controller and inverter integrated machine
Ø Industrial frequency isolation. Safe and reasonable
Ø Complete protection functions
Ø Comply with the CE certification
Technical Parameters
Model | WWSI0610-24 |
Wind Turbine Input | |
Rated input power | 600W |
Input voltage range | 0~32V |
Rated input current | 25A |
Brake by hand | Turn on the brake switch,and it will unload completely. Then, it need be recovered by manual operation |
Brake by over current | 25A |
Brake by overvoltage | Refer to "output overvoltage" control |
PV input | |
Rated input power | 180W |
Max. Open circuit voltage | 48V |
Rated input current | 8A |
Charge Parameters | |
Rated battery voltage | 24V |
Output overvoltage point | 29V |
AC Output | |
DC input voltage range | 21.6V~34V |
Undervoltage recovery point | Refer to "rated battery voltage" |
Rated output power | 1000VA |
Rated output voltage | 110/120/220/230/240V |
Rated phase number | Single phase |
Rated output frequency | 50/60±0.5Hz |
THDi | <5% |
Max. conversion efficiency | ≥85% |
Overload protection | 120% rated DC output -1min,150% rated DC output -10s |
General Parameters | |
Display mode | LCD |
Display information | Battery voltage, charge current, brake display, battery overvoltage/undervoltage, overload, load short circuit, and equipment overheat status. |
Isolation mode | Industrial frequency isolation |
Static loss | ≤0.8A |
Protection function | Lightning protection;Wind turbine: manual brake, automatic brake; PV:PV reversed connection protection, reversed charging protection; Battery: battery reversed connection protection, overvoltage protection; Load:overload protection, short circuit protection, overheating protection; and so on. |
Ambient temperature | -20℃~+40℃ |
Humidity | 0~90%, No condensing |
Noise | ≤65db |
Cooling mode | Forced air cooling |
Cover protection class | IP20 |
Product dimension (W*H*D) | 344*165*402 mm |
Product net weight | 15kg |
Note: Part of parameters can be adjusted according to customer’s specific demand. |