EEWSI 1000W
ENGELEC
EEWSI 1000W
EEWSI-1010 1000W Off-grid Integrated Controller&Inverter Data Sheet.pdf
| Availability: | |
|---|---|
EEWSI 1000W Off-grid Integrated Controller&Inverter 1000W Inverter
Applications
This product can be applied to household off-grid system and power supply for the coastal islands.
Features
Ø Wind&solar hybrid, controller and inverter integrated machine
Ø Industrial frequency isolation. Safe and reasonable
Ø Complete protection functions
Ø Comply with the CE certification
Technical Parameters
| Model | WWSI1010-48 |
| Wind Turbine Input | |
| Rated input power | 1000W |
| Input voltage range | 0~64V |
| Rated input current | 21A |
| Brake by hand | Turn on the brake switch,and it will unload completely. Then, it need be recovered by manual operation |
| Brake by over current | 21A |
| Brake by overvoltage | Refer to "output overvoltage" control |
| PV input | |
| Rated input power | 300W |
| Max. Open circuit voltage | 96V |
| Rated input current | 7A |
| Charge Parameters | |
| Rated battery voltage | 48V |
| Output overvoltage point | 58V |
| AC Output | |
| DC input voltage range | 43.2V~68V |
| Undervoltage recovery point | Refer to "rated battery voltage" |
| Rated output power | 1000VA |
| Rated output voltage | 110/120/220/230/240V |
| Rated phase number | Single phase |
| Rated output frequency | 50/60±0.5Hz |
| THDi | <5% |
| Max. conversion efficiency | ≥85% |
| Overload protection | 120% rated DC output -1min,150% rated DC output -10s |
| General Parameters | |
| Display mode | LCD |
| Display information | Battery voltage, charge current, brake display, battery overvoltage/undervoltage, overload, load short circuit, and equipment overheat status. |
| Isolation mode | Industrial frequency isolation |
| Static loss | ≤0.5A |
| Protection function | Lightning protection;Wind turbine: manual brake, automatic brake; PV:PV reversed connection protection, reversed charging protection; Battery: battery reversed connection protection, overvoltage protection; Load:overload protection, short circuit protection, overheating protection; and so on. |
| Ambient temperature | -20℃~+40℃ |
| Humidity | 0~90%, No condensing |
| Noise | ≤65db |
| Cooling mode | Forced air cooling |
| Cover protection class | IP20 |
| Product dimension (W*H*D) | 344*165*402 mm |
| Product net weight | 15kg |
| Note: Part of parameters can be adjusted according to customer’s specific demand. | |
EEWSI 1000W Off-grid Integrated Controller&Inverter 1000W Inverter
Applications
This product can be applied to household off-grid system and power supply for the coastal islands.
Features
Ø Wind&solar hybrid, controller and inverter integrated machine
Ø Industrial frequency isolation. Safe and reasonable
Ø Complete protection functions
Ø Comply with the CE certification
Technical Parameters
| Model | WWSI1010-48 |
| Wind Turbine Input | |
| Rated input power | 1000W |
| Input voltage range | 0~64V |
| Rated input current | 21A |
| Brake by hand | Turn on the brake switch,and it will unload completely. Then, it need be recovered by manual operation |
| Brake by over current | 21A |
| Brake by overvoltage | Refer to "output overvoltage" control |
| PV input | |
| Rated input power | 300W |
| Max. Open circuit voltage | 96V |
| Rated input current | 7A |
| Charge Parameters | |
| Rated battery voltage | 48V |
| Output overvoltage point | 58V |
| AC Output | |
| DC input voltage range | 43.2V~68V |
| Undervoltage recovery point | Refer to "rated battery voltage" |
| Rated output power | 1000VA |
| Rated output voltage | 110/120/220/230/240V |
| Rated phase number | Single phase |
| Rated output frequency | 50/60±0.5Hz |
| THDi | <5% |
| Max. conversion efficiency | ≥85% |
| Overload protection | 120% rated DC output -1min,150% rated DC output -10s |
| General Parameters | |
| Display mode | LCD |
| Display information | Battery voltage, charge current, brake display, battery overvoltage/undervoltage, overload, load short circuit, and equipment overheat status. |
| Isolation mode | Industrial frequency isolation |
| Static loss | ≤0.5A |
| Protection function | Lightning protection;Wind turbine: manual brake, automatic brake; PV:PV reversed connection protection, reversed charging protection; Battery: battery reversed connection protection, overvoltage protection; Load:overload protection, short circuit protection, overheating protection; and so on. |
| Ambient temperature | -20℃~+40℃ |
| Humidity | 0~90%, No condensing |
| Noise | ≤65db |
| Cooling mode | Forced air cooling |
| Cover protection class | IP20 |
| Product dimension (W*H*D) | 344*165*402 mm |
| Product net weight | 15kg |
| Note: Part of parameters can be adjusted according to customer’s specific demand. | |