EEWSB 200W
ENGELEC
| Availability: | |
|---|---|
EEWSB Series 200W Economic Wind/solar Hybrid Controller
Applications
Ø Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts.
Ø Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
Ø Apply for independent wind &solar hybrid system, lighting system and monitoring system.
Ø LED Display
Technical Parameters
| Model | EEWS02-12B |
| Wind Turbine Input | |
| Rated input power | 200W |
| Rated input voltage | 14Vdc |
| Input voltage range | 0~16Vdc |
| Rated input current | 17Adc |
| Manual brake | Press button “READ” “SET” at the same time to unload completely. Then recover by hand. |
| Brake by over current | 17A (factory default,0~17A settable) Unload completely when reached the set current, and recover automatically after working 10mins. |
| Brake by overvoltage | Refer to “output overvoltage” control |
| PV Input Parameters | |
| Rated input power | 100W |
| Max. open circuit voltage | 24V |
| Rated input current | 9A |
| Reversed connection protection | YES |
| Charge Parameters | |
| Rated battery voltage | 12V |
| Temperature compensation function (optional) | -3mV/℃/2V |
| Output Parameters | |
| Rated output voltage | 12V |
| Output overvoltage point | 14.5V (factory default,11Vdc~16Vdc settable) |
| Output overvoltage recovery point | 13.2V (factory default, reduce 1.3V from the output overvoltage point) |
| Max. Output current | 17A |
| DC Load Output Parameters | |
| Output loops | 2 loops |
| Output control mode | Both 2 loops could be set in 7 modes, such as light control on&off, light control on and time control off. |
| Output voltage range | 10.8V~16V |
| Undervoltage recovery point | Refer to "rated battery voltage" |
| Rated output current | 10A/each loop |
| Overload protection | 120% rated DC output -1min,150% rated DC output -10s |
| Short circuit protection | 200% rated DC output, instant protection |
| General Parameters | |
| Rectifier mode | Uncontrolled rectifier |
| Display mode | LED |
| Display information | Battery voltage, light control voltage, 1st loop output mode, 2nd loop output mode. Brake guidance. |
| Lightning protection | YES |
| Conversion efficiency | ≥95% |
| Static loss | <0.5W |
| Environment temperature | -20℃~+40℃ |
| Humidity | 5%~95%, No condensing |
| Noise | ≤65dB |
| Cooling mode | Natural cooling |
| Installation mode | Wall-mounted |
| Cover protection class | IP53 |
| Product dimension (W*H*D) | 123x150x62mm |
| Product net weight | 0.8kg |
| Note: the listed specs are just for your reference | |
EEWSB Series 200W Economic Wind/solar Hybrid Controller
Applications
Ø Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts.
Ø Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
Ø Apply for independent wind &solar hybrid system, lighting system and monitoring system.
Ø LED Display
Technical Parameters
| Model | EEWS02-12B |
| Wind Turbine Input | |
| Rated input power | 200W |
| Rated input voltage | 14Vdc |
| Input voltage range | 0~16Vdc |
| Rated input current | 17Adc |
| Manual brake | Press button “READ” “SET” at the same time to unload completely. Then recover by hand. |
| Brake by over current | 17A (factory default,0~17A settable) Unload completely when reached the set current, and recover automatically after working 10mins. |
| Brake by overvoltage | Refer to “output overvoltage” control |
| PV Input Parameters | |
| Rated input power | 100W |
| Max. open circuit voltage | 24V |
| Rated input current | 9A |
| Reversed connection protection | YES |
| Charge Parameters | |
| Rated battery voltage | 12V |
| Temperature compensation function (optional) | -3mV/℃/2V |
| Output Parameters | |
| Rated output voltage | 12V |
| Output overvoltage point | 14.5V (factory default,11Vdc~16Vdc settable) |
| Output overvoltage recovery point | 13.2V (factory default, reduce 1.3V from the output overvoltage point) |
| Max. Output current | 17A |
| DC Load Output Parameters | |
| Output loops | 2 loops |
| Output control mode | Both 2 loops could be set in 7 modes, such as light control on&off, light control on and time control off. |
| Output voltage range | 10.8V~16V |
| Undervoltage recovery point | Refer to "rated battery voltage" |
| Rated output current | 10A/each loop |
| Overload protection | 120% rated DC output -1min,150% rated DC output -10s |
| Short circuit protection | 200% rated DC output, instant protection |
| General Parameters | |
| Rectifier mode | Uncontrolled rectifier |
| Display mode | LED |
| Display information | Battery voltage, light control voltage, 1st loop output mode, 2nd loop output mode. Brake guidance. |
| Lightning protection | YES |
| Conversion efficiency | ≥95% |
| Static loss | <0.5W |
| Environment temperature | -20℃~+40℃ |
| Humidity | 5%~95%, No condensing |
| Noise | ≤65dB |
| Cooling mode | Natural cooling |
| Installation mode | Wall-mounted |
| Cover protection class | IP53 |
| Product dimension (W*H*D) | 123x150x62mm |
| Product net weight | 0.8kg |
| Note: the listed specs are just for your reference | |