EEWS 2000W
ENGELEC
| Availability: | |
|---|---|
EEWS Series 2000W Wind/solar Hybrid Controller
Applications
Ø Independent wind power plant
Ø Independent household wind power generation system
Ø Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts.
Ø Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
Ø Can be applied to wind&solar hybrid off-grid system
Ø Several functions are optional, such as wind speed measure function, rotational speed control function and temperature compensation function.
Ø RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee optional. ( It can be monitored by app for those with GPRS/WIFI/Bluetooth connection)
Technical Parameters
| Model | EEWS20-120 | EEWS20-48 |
| Wind Turbine Input | ||
| Rated input power | 2kW | |
| Rated input voltage | 120Vdc | 48Vdc |
| Input voltage range | 0~160Vdc | 0~64Vdc |
| Rated input current | 17A | 42A |
| Brake by hand | Keep press the button for 5s to unload completely, and then recover by hand. | |
| Switch “ON” the brake switch | ||
| Brake by over current | 17A (factory default, 0~17A settable) unload completely when reached the set current, and recover automatically after working 10mins. | 42A (factory default, 0~42A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
| Brake by overvoltage | Refer to “output overvoltage” control | |
| Brake by over wind speed (optional) | 18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after working 10mins. | |
| Brake by over rotational Speed (optional) | 500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. | |
| PV Input | ||
| Rated input power | 600W | |
| Max. Open circuit voltage | 240Vdc | 96Vdc |
| Rated input current | 5A | 13A |
| Reversed connection protection | YES | YES |
| Charge Parameters | ||
| Rated battery voltage | 120Vdc | 48Vdc |
| Temperature compensation function (optional) | -3mV/℃/2V | |
| Output Parameters | ||
| Rated output voltage | 120Vdc | |
| Output overvoltage point | 145Vdc | |
| output overvoltage recovery point | it will recover automatically once it is lower than output overvoltage point. | |
| Max. Output current | 17A | |
| General Parameters | ||
| Rectifier mode | Uncontrolled rectifier | |
| Display mode | LCD | |
| Display information | DC output voltage, wind voltage/current/power, battery voltage, PV voltage/current/power. | |
| Monitoring mode (optional) | RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee | |
| Monitoring Contents | DC output voltage, wind voltage/current/power, battery voltage, PV voltage/current/power. | |
| parameter setting: output overvoltage point, wind overcurrent point and manual brake | ||
| Lightning protection | YES | |
| Conversion efficiency | ≥95% | |
| Static loss | <2W | <1W |
| Ambient temperature | -20℃~+40℃ | |
| Humidity | 0~90%, No condensing | |
| Noise | ≤65dB | |
| Cooling mode | Natural cooling | |
| Installation mode | Wall-mounted | |
| Cover protection class | IP20 | |
| Product dimension (W*H*D) | 420×440×175 mm | |
| Product net weight | 11.5kG | |
EEWS Series 2000W Wind/solar Hybrid Controller
Applications
Ø Independent wind power plant
Ø Independent household wind power generation system
Ø Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts.
Ø Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
Ø Can be applied to wind&solar hybrid off-grid system
Ø Several functions are optional, such as wind speed measure function, rotational speed control function and temperature compensation function.
Ø RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee optional. ( It can be monitored by app for those with GPRS/WIFI/Bluetooth connection)
Technical Parameters
| Model | EEWS20-120 | EEWS20-48 |
| Wind Turbine Input | ||
| Rated input power | 2kW | |
| Rated input voltage | 120Vdc | 48Vdc |
| Input voltage range | 0~160Vdc | 0~64Vdc |
| Rated input current | 17A | 42A |
| Brake by hand | Keep press the button for 5s to unload completely, and then recover by hand. | |
| Switch “ON” the brake switch | ||
| Brake by over current | 17A (factory default, 0~17A settable) unload completely when reached the set current, and recover automatically after working 10mins. | 42A (factory default, 0~42A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
| Brake by overvoltage | Refer to “output overvoltage” control | |
| Brake by over wind speed (optional) | 18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after working 10mins. | |
| Brake by over rotational Speed (optional) | 500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. | |
| PV Input | ||
| Rated input power | 600W | |
| Max. Open circuit voltage | 240Vdc | 96Vdc |
| Rated input current | 5A | 13A |
| Reversed connection protection | YES | YES |
| Charge Parameters | ||
| Rated battery voltage | 120Vdc | 48Vdc |
| Temperature compensation function (optional) | -3mV/℃/2V | |
| Output Parameters | ||
| Rated output voltage | 120Vdc | |
| Output overvoltage point | 145Vdc | |
| output overvoltage recovery point | it will recover automatically once it is lower than output overvoltage point. | |
| Max. Output current | 17A | |
| General Parameters | ||
| Rectifier mode | Uncontrolled rectifier | |
| Display mode | LCD | |
| Display information | DC output voltage, wind voltage/current/power, battery voltage, PV voltage/current/power. | |
| Monitoring mode (optional) | RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee | |
| Monitoring Contents | DC output voltage, wind voltage/current/power, battery voltage, PV voltage/current/power. | |
| parameter setting: output overvoltage point, wind overcurrent point and manual brake | ||
| Lightning protection | YES | |
| Conversion efficiency | ≥95% | |
| Static loss | <2W | <1W |
| Ambient temperature | -20℃~+40℃ | |
| Humidity | 0~90%, No condensing | |
| Noise | ≤65dB | |
| Cooling mode | Natural cooling | |
| Installation mode | Wall-mounted | |
| Cover protection class | IP20 | |
| Product dimension (W*H*D) | 420×440×175 mm | |
| Product net weight | 11.5kG | |