EEWI 20KVA
ENGELEC
EEWI 10KVA
Availability: | |
---|---|
EEWI 20KVA Pure Sine Wave Power Inverter Off-grid Single Phase
Applications
Ø Application in wind, Solar, Wind&Solar hybrid power generation station.
Ø Application in household wind&solar hybrid power generation system.
Ø Power supply for those unmanned regions like the coastal islands, remote mountainous regions and border posts.
Features
Ø Can be applied in wind, solar, wind&solar hybrid power generation system
Ø Simple structure, complete function
Ø Low no-load loss by using industrial frequency transformer
Ø Comply with the CE certification
Technical Parameters
Model | EEWI200-240 |
DC Input Parameters | |
Rated battery voltage | 240Vdc |
Input overvoltage point | 340Vdc |
Input overvoltage recovery point | 330Vdc |
Input undervoltage point | 216Vdc |
Input undervoltage recovery point | 240Vdc |
AC Output Parameters | |
Output phase number | Single phase |
Rated output power | 20KVA |
Rated output voltage | 110/120/220/230/240Vac |
Rated output frequency | 50/60±0.5HZ |
THDi | <5% |
Efficiency | |
Max. conversion efficiency | ≥85% |
Protection Functions | |
DC input overvoltage protection | YES |
DC reversed connection protection | YES |
AC output overload protection | YES |
AC short circuit protection | YES |
Surge protection | YES |
Over-temperature protection | YES |
General Parameters | |
Display mode | LCD |
Display information | Battery voltage, inverter voltage, inverter current, inverter power, and working status of battery overvoltage/undervoltage and AC output overload/short circuit. |
Monitoring mode(optional) | RS232/RS485/GPRS |
Monitoring Contents | Real-time display: Battery voltage, inverter voltage, inverter current, inverter power, and working status of battery overvoltage/.undervoltage and AC output overload/short circuit. Parameter setting: overvoltage point, overvoltage recovery point, undervoltage point, and undervoltage recovery point. |
Isolation mode | Industrial frequency isolation |
No-load current | ≤0.9A |
Environment temperature | -20℃~+40℃ |
Humidity | 5%~95%, No condensing |
Noise | <60dB |
Cooling mode | Natural cooling |
Cover protection class | IP20 |
Note: the listed specs are just for your reference |
Project
EEWI 20KVA Pure Sine Wave Power Inverter Off-grid Single Phase
Applications
Ø Application in wind, Solar, Wind&Solar hybrid power generation station.
Ø Application in household wind&solar hybrid power generation system.
Ø Power supply for those unmanned regions like the coastal islands, remote mountainous regions and border posts.
Features
Ø Can be applied in wind, solar, wind&solar hybrid power generation system
Ø Simple structure, complete function
Ø Low no-load loss by using industrial frequency transformer
Ø Comply with the CE certification
Technical Parameters
Model | EEWI200-240 |
DC Input Parameters | |
Rated battery voltage | 240Vdc |
Input overvoltage point | 340Vdc |
Input overvoltage recovery point | 330Vdc |
Input undervoltage point | 216Vdc |
Input undervoltage recovery point | 240Vdc |
AC Output Parameters | |
Output phase number | Single phase |
Rated output power | 20KVA |
Rated output voltage | 110/120/220/230/240Vac |
Rated output frequency | 50/60±0.5HZ |
THDi | <5% |
Efficiency | |
Max. conversion efficiency | ≥85% |
Protection Functions | |
DC input overvoltage protection | YES |
DC reversed connection protection | YES |
AC output overload protection | YES |
AC short circuit protection | YES |
Surge protection | YES |
Over-temperature protection | YES |
General Parameters | |
Display mode | LCD |
Display information | Battery voltage, inverter voltage, inverter current, inverter power, and working status of battery overvoltage/undervoltage and AC output overload/short circuit. |
Monitoring mode(optional) | RS232/RS485/GPRS |
Monitoring Contents | Real-time display: Battery voltage, inverter voltage, inverter current, inverter power, and working status of battery overvoltage/.undervoltage and AC output overload/short circuit. Parameter setting: overvoltage point, overvoltage recovery point, undervoltage point, and undervoltage recovery point. |
Isolation mode | Industrial frequency isolation |
No-load current | ≤0.9A |
Environment temperature | -20℃~+40℃ |
Humidity | 5%~95%, No condensing |
Noise | <60dB |
Cooling mode | Natural cooling |
Cover protection class | IP20 |
Note: the listed specs are just for your reference |