Professional manufacturer of vertical & horizontal wind turbine generator, PMG generator
 info@engelec.cn 
Home » Wind Power Inverters » Off-grid Inverters » Single Phase » EEWI 10KVA Pure Sine Wave Power Inverter Off-grid Single Phase

Product Center

loading

Share to:
sharethis sharing button

EEWI 10KVA Pure Sine Wave Power Inverter Off-grid Single Phase

EEWI 10KVA Can be applied in wind, solar, wind&solar hybrid power generation system;Simple structure, complete function Low no-load loss by using industrial frequency transformer;Comply with the CE certification
Availability:

EEWI 10KVA Pure Sine Wave Power Inverter Off-grid Single Phase


connection


Applications

Ø  Application in wind, Solar, Wind&Solar hybrid power generation station.

Ø  Application in household wind&solar hybrid power generation system.

Ø  Power supply for those unmanned regions like the coastal islands, remote mountainous regions and border posts.


Features

Ø  Can be applied in wind, solar, wind&solar hybrid power generation system

Ø  Simple structure, complete function

Ø  Low no-load loss by using industrial frequency transformer

Ø  Comply with the CE certification


Technical Parameters

Model WI100-120 WI100-240
DC Input Parameters
Rated battery voltage 120Vdc 240Vdc
Input overvoltage point 170Vdc 340Vdc
Input overvoltage recovery point 165Vdc 330Vdc
Input undervoltage point 108Vdc 216Vdc
Input undervoltage recovery point 120Vdc 240Vdc
AC Output Parameters
Output phase number Single   phase
Rated output power 10KVA 10KVA
Rated output voltage 110/120/220/230/240Vac
Rated output frequency 50/60±0.5HZ
THDi <5%
Efficiency
Max. conversion efficiency ≥85%
Protection Functions
DC input overvoltage protection YES
DC reversed connection protection YES
AC output overload protection YES
AC short circuit protection YES
Surge protection YES
Over-temperature protection YES
General Parameters
Display mode LCD
Display information Battery   voltage, inverter voltage, inverter current, inverter power, and working   status of battery overvoltage/undervoltage and AC output overload/short   circuit.
Monitoring mode(optional) RS232/RS485/GPRS
Monitoring Contents Real-time   display: Battery voltage, inverter voltage, inverter current, inverter power,   and working status of battery overvoltage/.undervoltage and AC output   overload/short circuit.  Parameter setting: overvoltage point, overvoltage recovery point,   undervoltage point, and undervoltage recovery point.
Isolation mode Industrial   frequency isolation
No-load current ≤1.5A ≤0.5A
Environment temperature  -20℃~+40℃
Humidity 5%~95%,   No condensing
Noise <60dB
Cooling mode Natural   cooling
Cover protection class IP20
Note:  the listed specs   are just for your reference


Project

控制器详情

Previous: 
Next: 
Product Inquiry
 24 hours of service
Contact us
Contact information

Quick Contact

Tel:  +86 577 61672337 
Phone:+86 13505876536
Email:  info@engelec.cn
 

Our Office

Street:No.138 Ninkang West Road, Yueqing, Zhejiang, China(325600) 
City:wenzhou

     

Other Ways

Skype:  jolininternational
wetchat: +86 135 0587 6536

     
 Copyright  2016 ENGELEC POWER TECHNOLOGY CO., LTD.  XML SiteMap
We use cookies to enable all functionalities for best performance during your visit and to improve our services by giving us some insight into how the website is being used. Continued use of our website without having changed your browser settings confirms your acceptance of these cookies. For details please see our privacy policy.
×