EESWS 300W
ENGELEC
| Availability: | |
|---|---|
EESWS Series 300W Wind/solar Hybrid Controller
Applications
Ø Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts.
Ø Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
Ø Wind&Solar complementary controller in high quality.
Ø LCD Display. Easy setup.
Ø RS232/RS485/RJ45/GPRS /Bluetooth Optional (For those with GPRS/Bluetooth/RJ45 can also be monitored through App.)
Technical Parameters
| Model | EESWS03-12 | |
| Wind Turbine Input | ||
| Rated input power | 300W | |
| Rated input voltage | 14Vdc | |
| Input voltage range | 0~16Vdc | |
| Rated input current | 25Adc | |
| Brake by hand | Press button “Enter” “Esc” at the same time to unload completely. Then recover by hand. | |
| Brake by over current | 25A(factory default,0~25A settable)Unload completely when reached the set current, and recover automatically after working 10mins. | |
| Brake by overvoltage | Refer to “output overvoltage” control | |
| Brake by over wind speed(optional) | 14m/s(0-30m/s settable),Unload completely when reached the set wind speed, and recover automatically after working 10mins. | |
| Brake by over rotational Speed(optional) | 500r/min(factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. | |
| PV Input Parameters | ||
| Rated input power | 150W | |
| Max. open circuit voltage | 24V | |
| Rated input current | 13A | |
| Reversed connection protection | YES | |
| Charge Parameters | ||
| Rated battery voltage | 12V | |
| Temperature compensation function(optional) | -3mV/℃/2V | |
| Output Parameters | ||
| Rated output voltage | 12V | |
| Start unload voltage | 13.5V(factory default,11Vdc~16Vdc settable) | |
| Complete unload voltage | 14.5V(factory default, add 1V to the start unload voltage) | |
| Max. Output current | 25A | |
| DC load output | ||
| Output loops | 2 loops | |
| Output control mode | Both 2 loops could be set in 7 modes, such as light control on&off, light control on and time control off. | |
| Output voltage range | 10.8V~16V | |
| Undervoltage recovery point | Refer to "rated battery voltage" | |
| Rated output current | 10A/each loop | |
| Overload protection | 120% rated DC output -1min,150% rated DC output -10s | |
| Short circuit protection | 200% rated DC output, instant protection | |
| General Parameters | ||
| Rectifier mode | Uncontrolled rectifier | |
| Display mode | LCD | |
| Display information | Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, light control-on voltage, light control-off voltage, time control duration, load current and so on. | |
| Monitoring mode(optional) | RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee | |
| Monitoring Contents | Real-time display: Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, wind power generation capacity, solar power generation capacity, Battery status, wind turbine status, day and night, DC overload, DC load short circuit, and so on. | |
| Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, DC load overvoltage/undervoltage recovery point, output mode choice for two loops, light control on voltage, light control off voltage, and wind turbine brake settings. | ||
| Lightning protection | YES | |
| Conversion efficiency | ≥95% | |
| Static loss | <0.5W | |
| Environment temperature | -20℃~+40℃ | |
| Humidity | 5%~95%,No condensing | |
| Noise | ≤65dB | |
| Cooling mode | Natural cooling | |
| Installation mode | Wall-mounted | |
| Cover protection class | IP52 | |
| Product dimension(W*H*D) | 150×143×83mm | |
| Product net weight | 1.8kg | |
| Note: the listed specs are just for your reference | ||
EESWS Series 300W Wind/solar Hybrid Controller
Applications
Ø Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts.
Ø Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
Ø Wind&Solar complementary controller in high quality.
Ø LCD Display. Easy setup.
Ø RS232/RS485/RJ45/GPRS /Bluetooth Optional (For those with GPRS/Bluetooth/RJ45 can also be monitored through App.)
Technical Parameters
| Model | EESWS03-12 | |
| Wind Turbine Input | ||
| Rated input power | 300W | |
| Rated input voltage | 14Vdc | |
| Input voltage range | 0~16Vdc | |
| Rated input current | 25Adc | |
| Brake by hand | Press button “Enter” “Esc” at the same time to unload completely. Then recover by hand. | |
| Brake by over current | 25A(factory default,0~25A settable)Unload completely when reached the set current, and recover automatically after working 10mins. | |
| Brake by overvoltage | Refer to “output overvoltage” control | |
| Brake by over wind speed(optional) | 14m/s(0-30m/s settable),Unload completely when reached the set wind speed, and recover automatically after working 10mins. | |
| Brake by over rotational Speed(optional) | 500r/min(factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. | |
| PV Input Parameters | ||
| Rated input power | 150W | |
| Max. open circuit voltage | 24V | |
| Rated input current | 13A | |
| Reversed connection protection | YES | |
| Charge Parameters | ||
| Rated battery voltage | 12V | |
| Temperature compensation function(optional) | -3mV/℃/2V | |
| Output Parameters | ||
| Rated output voltage | 12V | |
| Start unload voltage | 13.5V(factory default,11Vdc~16Vdc settable) | |
| Complete unload voltage | 14.5V(factory default, add 1V to the start unload voltage) | |
| Max. Output current | 25A | |
| DC load output | ||
| Output loops | 2 loops | |
| Output control mode | Both 2 loops could be set in 7 modes, such as light control on&off, light control on and time control off. | |
| Output voltage range | 10.8V~16V | |
| Undervoltage recovery point | Refer to "rated battery voltage" | |
| Rated output current | 10A/each loop | |
| Overload protection | 120% rated DC output -1min,150% rated DC output -10s | |
| Short circuit protection | 200% rated DC output, instant protection | |
| General Parameters | ||
| Rectifier mode | Uncontrolled rectifier | |
| Display mode | LCD | |
| Display information | Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, light control-on voltage, light control-off voltage, time control duration, load current and so on. | |
| Monitoring mode(optional) | RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee | |
| Monitoring Contents | Real-time display: Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, wind power generation capacity, solar power generation capacity, Battery status, wind turbine status, day and night, DC overload, DC load short circuit, and so on. | |
| Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, DC load overvoltage/undervoltage recovery point, output mode choice for two loops, light control on voltage, light control off voltage, and wind turbine brake settings. | ||
| Lightning protection | YES | |
| Conversion efficiency | ≥95% | |
| Static loss | <0.5W | |
| Environment temperature | -20℃~+40℃ | |
| Humidity | 5%~95%,No condensing | |
| Noise | ≤65dB | |
| Cooling mode | Natural cooling | |
| Installation mode | Wall-mounted | |
| Cover protection class | IP52 | |
| Product dimension(W*H*D) | 150×143×83mm | |
| Product net weight | 1.8kg | |
| Note: the listed specs are just for your reference | ||