EESWS 1000W
ENGELEC
Availability: | |
---|---|
EESWS Series 1000W Wind/solar Hybrid Controller
Applications
Ø Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts.
Ø Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
Ø Wind&Solar complementary controller in high quality.
Ø LCD Display. Easy setup.
Ø RS232/RS485/RJ45/GPRS /Bluetooth Optional (For those with GPRS/Bluetooth/RJ45 can also be monitored through App.)
Technical Parameters
Model | WWS10B-48 |
Wind Turbine Input | |
Rated input power | 1kW |
Rated input voltage | 56Vdc |
Input voltage range | 0~64Vdc |
Rated input current | 21Adc |
Brake by hand | Press button “Enter” “Esc” at the same time to unload completely. Then recover by hand. |
Brake by over current | 21A (factory default,0~21A settable)Unload completely when reached the set current, and recover automatically after working 10mins. |
Brake by overvoltage | Refer to “output overvoltage” control |
Brake by over wind speed (optional) | 14m/s (0-30m/s settable),Unload completely when reached the set wind speed, and recover automatically after working 10mins. |
Brake by over rotational Speed (optional) | 500r/min (factory default,0~1000 r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
PV Input Parameters (Optional) | |
Rated input power | 300W |
Max. open circuit voltage | 96Vdc |
Rated input current | 7Adc |
Reversed connection protection | YES |
Charge Parameters | |
Rated battery voltage | 48Vdc |
Temperature compensation function (optional) | -3mV/℃/2V |
Output Parameters | |
Rated output voltage | 48Vdc |
Output overvoltage point | 58V |
Output overvoltage recovery point | Recover automatically under output overvoltage point |
Max. Output current | 21Adc |
General Parameters | |
Rectifier mode | Uncontrolled rectifier |
Display mode | LCD |
Display information | Battery voltage, wind turbine voltage/current/power. |
For those with PV, PV voltage/current/power is showed as well. | |
Monitoring mode (optional) | RS232/RS485/ GPRS/Bluetooth/Zigbee |
Monitoring Contents | Real-time display: Battery voltage, wind turbine voltage/current/power. |
For those with PV, PV voltage/current/power is showed as well. | |
Parameter setting: overvoltage point, over current point, wind turbine brake settings, and so on. | |
Lightning protection | YES |
Conversion efficiency | ≥95% |
Static loss | <1W |
Environment temperature | -20℃~+40℃ |
Humidity | 5%~95%,No condensing |
Noise | ≤65dB |
Cooling mode | Natural cooling |
Installation mode | Wall-mounted |
Cover protection class | IP52 |
Product dimension (W*H*D) | 150×205×80mm |
Product net weight | 2.6kg |
Dump load dimension (W*H*D) | 360×80×120mm |
Dump load net weight | 2.8kg |
Note: the listed specs are just for your reference |
EESWS Series 1000W Wind/solar Hybrid Controller
Applications
Ø Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts.
Ø Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
Ø Wind&Solar complementary controller in high quality.
Ø LCD Display. Easy setup.
Ø RS232/RS485/RJ45/GPRS /Bluetooth Optional (For those with GPRS/Bluetooth/RJ45 can also be monitored through App.)
Technical Parameters
Model | WWS10B-48 |
Wind Turbine Input | |
Rated input power | 1kW |
Rated input voltage | 56Vdc |
Input voltage range | 0~64Vdc |
Rated input current | 21Adc |
Brake by hand | Press button “Enter” “Esc” at the same time to unload completely. Then recover by hand. |
Brake by over current | 21A (factory default,0~21A settable)Unload completely when reached the set current, and recover automatically after working 10mins. |
Brake by overvoltage | Refer to “output overvoltage” control |
Brake by over wind speed (optional) | 14m/s (0-30m/s settable),Unload completely when reached the set wind speed, and recover automatically after working 10mins. |
Brake by over rotational Speed (optional) | 500r/min (factory default,0~1000 r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
PV Input Parameters (Optional) | |
Rated input power | 300W |
Max. open circuit voltage | 96Vdc |
Rated input current | 7Adc |
Reversed connection protection | YES |
Charge Parameters | |
Rated battery voltage | 48Vdc |
Temperature compensation function (optional) | -3mV/℃/2V |
Output Parameters | |
Rated output voltage | 48Vdc |
Output overvoltage point | 58V |
Output overvoltage recovery point | Recover automatically under output overvoltage point |
Max. Output current | 21Adc |
General Parameters | |
Rectifier mode | Uncontrolled rectifier |
Display mode | LCD |
Display information | Battery voltage, wind turbine voltage/current/power. |
For those with PV, PV voltage/current/power is showed as well. | |
Monitoring mode (optional) | RS232/RS485/ GPRS/Bluetooth/Zigbee |
Monitoring Contents | Real-time display: Battery voltage, wind turbine voltage/current/power. |
For those with PV, PV voltage/current/power is showed as well. | |
Parameter setting: overvoltage point, over current point, wind turbine brake settings, and so on. | |
Lightning protection | YES |
Conversion efficiency | ≥95% |
Static loss | <1W |
Environment temperature | -20℃~+40℃ |
Humidity | 5%~95%,No condensing |
Noise | ≤65dB |
Cooling mode | Natural cooling |
Installation mode | Wall-mounted |
Cover protection class | IP52 |
Product dimension (W*H*D) | 150×205×80mm |
Product net weight | 2.6kg |
Dump load dimension (W*H*D) | 360×80×120mm |
Dump load net weight | 2.8kg |
Note: the listed specs are just for your reference |