EESNB 50KW
ENGELEC
EESNB 50KW
Availability: | |
---|---|
EESNB 50KW Off-Grid Power Frequency Inverter Three phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
Type | EESNB50-220 | EESNB50-380 | |
DC input | Input rated voltage | 220 VDC | 380 VDC |
Input rated current | 252 A | 146.7A | |
Input DC voltage allowing range | 180-280 VDC | 320-500VDC | |
AC input (AC bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 139A / 76A / 72.5A | ||
Bypass transfer time | ≤100ms(4ms optional) | ||
AC output | Rated capacity | 50KVA | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
Output rated current | 139A / 76A / 72.5A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 2% | ||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
Wave | Pure sine wave (Isolation transformer) | ||
THD. | ≤3%(Linear load) | ||
Power factor (PF) | 0.8 | ||
Overload capacity | 120%,10 minutes | ||
Overcurrent capacity | 200%,10 seconds | ||
Crest factor (CF) | 3:01 | ||
Inverter efficiency | >92% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -10℃~+50℃ | ||
Humidity | 0~90%, No condensation | ||
Altitude | <2000m | ||
Higher than 2000m rated power should be reduced | |||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||
Pure Sine Wave | Yes | ||
Equipped With Copper Transformer | Yes | ||
Solar Charger | Optional | ||
AC Charger | Optional | ||
Generator Port | Optional | ||
Size | 710*1410*1710 mm | ||
Weight | 505 kg |
Project Sample
EESNB 50KW Off-Grid Power Frequency Inverter Three phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
Type | EESNB50-220 | EESNB50-380 | |
DC input | Input rated voltage | 220 VDC | 380 VDC |
Input rated current | 252 A | 146.7A | |
Input DC voltage allowing range | 180-280 VDC | 320-500VDC | |
AC input (AC bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 139A / 76A / 72.5A | ||
Bypass transfer time | ≤100ms(4ms optional) | ||
AC output | Rated capacity | 50KVA | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
Output rated current | 139A / 76A / 72.5A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 2% | ||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
Wave | Pure sine wave (Isolation transformer) | ||
THD. | ≤3%(Linear load) | ||
Power factor (PF) | 0.8 | ||
Overload capacity | 120%,10 minutes | ||
Overcurrent capacity | 200%,10 seconds | ||
Crest factor (CF) | 3:01 | ||
Inverter efficiency | >92% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -10℃~+50℃ | ||
Humidity | 0~90%, No condensation | ||
Altitude | <2000m | ||
Higher than 2000m rated power should be reduced | |||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||
Pure Sine Wave | Yes | ||
Equipped With Copper Transformer | Yes | ||
Solar Charger | Optional | ||
AC Charger | Optional | ||
Generator Port | Optional | ||
Size | 710*1410*1710 mm | ||
Weight | 505 kg |
Project Sample