EESNB 200KW
ENGELEC
EESNB 200KW
| Availability: | |
|---|---|
EESNB 200KW Off-Grid Power Frequency Inverter Three phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
| Type | EESNB200-380 | EESNB200-480 | |
| DC input | Input rated voltage | 380 VDC | 480 VDC |
| Input rated current | 584.4 A | 463.3A | |
| Input DC voltage allowing range | 320-500 VDC | 400-620 VDC | |
| AC input (AC bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
| Input rated current | 550A / 300A / 290A | ||
| Bypass transfer time | ≤100ms(4ms optional) | ||
| AC output | Rated capacity | 200KVA | |
| Output rated power | 160KW | ||
| Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
| Output rated current | 550A / 300A / 290A | ||
| Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 2% | ||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
| Wave | Pure sine wave (Isolation transformer) | ||
| THD. | ≤3%(Linear load) | ||
| Power factor (PF) | 0.8 | ||
| Overload capacity | 120%,10 minutes | ||
| Overcurrent capacity | 200%,10 seconds | ||
| Crest factor (CF) | 0.125694444 | ||
| Working Environment | Inverter efficiency | >95% | |
| Dielectric strength | 1500VAC,1minute | ||
| Noise (1m) | ≤50dB | ||
| Ambient temperature | -10℃~+50℃ | ||
| Humidity | 0~90%, No condensation | ||
| Altitude | <2000m Higher than 2000m rated power should be reduced | ||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
| Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||
| Pure Sine Wave | Yes | ||
| Equipped With Copper Transformer | Yes | ||
| Solar Charger | Optional | ||
| AC Charger | Optional | ||
| Generator Port | Optional | ||
| Size | 1280*2000*2060mm | ||
| Weight | 2000 kg | ||
Project Sample
EESNB 200KW Off-Grid Power Frequency Inverter Three phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
| Type | EESNB200-380 | EESNB200-480 | |
| DC input | Input rated voltage | 380 VDC | 480 VDC |
| Input rated current | 584.4 A | 463.3A | |
| Input DC voltage allowing range | 320-500 VDC | 400-620 VDC | |
| AC input (AC bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
| Input rated current | 550A / 300A / 290A | ||
| Bypass transfer time | ≤100ms(4ms optional) | ||
| AC output | Rated capacity | 200KVA | |
| Output rated power | 160KW | ||
| Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
| Output rated current | 550A / 300A / 290A | ||
| Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 2% | ||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
| Wave | Pure sine wave (Isolation transformer) | ||
| THD. | ≤3%(Linear load) | ||
| Power factor (PF) | 0.8 | ||
| Overload capacity | 120%,10 minutes | ||
| Overcurrent capacity | 200%,10 seconds | ||
| Crest factor (CF) | 0.125694444 | ||
| Working Environment | Inverter efficiency | >95% | |
| Dielectric strength | 1500VAC,1minute | ||
| Noise (1m) | ≤50dB | ||
| Ambient temperature | -10℃~+50℃ | ||
| Humidity | 0~90%, No condensation | ||
| Altitude | <2000m Higher than 2000m rated power should be reduced | ||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
| Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||
| Pure Sine Wave | Yes | ||
| Equipped With Copper Transformer | Yes | ||
| Solar Charger | Optional | ||
| AC Charger | Optional | ||
| Generator Port | Optional | ||
| Size | 1280*2000*2060mm | ||
| Weight | 2000 kg | ||
Project Sample