EEDNB 5KW
ENGELEC
EEDNB 5KW
Availability: | |
---|---|
EEDNB 5KW Off-Grid Power Frequency Inverter Single phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
Model | EEDNB05-48 | EEDNB05-96 | EEDNB05-110 | EEDNB05-220 | |
DC input | Input rated voltage | 48 VDC | 96 VDC | 110 VDC | 220 VDC |
Input rated current | 119A | 52A | 45.5A | 22.7A | |
Input DC voltage allowing range | 40-60 VDC | 75-135 VDC | 80-145 VDC | 180-300 VDC | |
AC bypass | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | |||
Input rated current | 45.5A / 41.7A / 22.5 A / 21A | ||||
Bypass transfer time | ≤4 ms | ||||
AC output | Rated capacity | 5KVA | |||
Output rated power | 4KW | ||||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||||
Output rated current | 45.5A / 41.7A / 22.5 A / 21A | ||||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | ||||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||||
Wave | Pure sine wave (Isolation transformer) | ||||
THD. | ≤3%(Linear load) | ||||
Power factor (PF) | 0.8 | ||||
Overload capacity | 120%,3 minutes,150%,10 second | ||||
Crest factor (CF) | 3:01 | ||||
Inverter efficiency | >90% | ||||
Working Environment | Dielectric strength | 1500VAC,1minute | |||
Noise (1m) | ≤50dB | ||||
Ambient temperature | -10℃~+50℃ | ||||
Humidity | 0~90%, No condensation | ||||
Altitude | <3000m Higher than 3000m rated power should be reduced | ||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||||
Size | 510*660*850 mm | ||||
Weight | 75 Kg |
Project Sample
EEDNB 5KW Off-Grid Power Frequency Inverter Single phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
Model | EEDNB05-48 | EEDNB05-96 | EEDNB05-110 | EEDNB05-220 | |
DC input | Input rated voltage | 48 VDC | 96 VDC | 110 VDC | 220 VDC |
Input rated current | 119A | 52A | 45.5A | 22.7A | |
Input DC voltage allowing range | 40-60 VDC | 75-135 VDC | 80-145 VDC | 180-300 VDC | |
AC bypass | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | |||
Input rated current | 45.5A / 41.7A / 22.5 A / 21A | ||||
Bypass transfer time | ≤4 ms | ||||
AC output | Rated capacity | 5KVA | |||
Output rated power | 4KW | ||||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||||
Output rated current | 45.5A / 41.7A / 22.5 A / 21A | ||||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | ||||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||||
Wave | Pure sine wave (Isolation transformer) | ||||
THD. | ≤3%(Linear load) | ||||
Power factor (PF) | 0.8 | ||||
Overload capacity | 120%,3 minutes,150%,10 second | ||||
Crest factor (CF) | 3:01 | ||||
Inverter efficiency | >90% | ||||
Working Environment | Dielectric strength | 1500VAC,1minute | |||
Noise (1m) | ≤50dB | ||||
Ambient temperature | -10℃~+50℃ | ||||
Humidity | 0~90%, No condensation | ||||
Altitude | <3000m Higher than 3000m rated power should be reduced | ||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||||
Size | 510*660*850 mm | ||||
Weight | 75 Kg |
Project Sample