EEDNB 20KW
ENGELEC
EEDNB 20KW
Availability: | |
---|---|
EEDNB 20KW Off-Grid Power Frequency Inverter Single phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
Model | EEDNB20-96 | EEDNB20-110 | EEDNB20-220 | |
DC input | Input rated voltage | 96 VDC | 110 VDC | 220 VDC |
Input rated current | 208 A | 182 A | 91 A | |
Input DC voltage allowing range | 75-135 VDC | 80-145 VDC | 180-300 VDC | |
AC Bypass | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | ||
Input rated current | 182A / 167A / 91 A / 83A | |||
Bypass transfer time | ≤4 ms | |||
AC output | Output rated power | 16KW | ||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
Output rated current | 182A / 167A / 91 A / 83A | |||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | |||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |||
Wave | Pure sine wave (Isolation transformer) | |||
THD. | ≤3%(Linear load) | |||
Power factor (PF) | 0.8 | |||
Overload capacity | 120%,3 minutes,150%,10 second | |||
Crest factor (CF) | 3:01 | |||
Inverter efficiency | >90% | |||
Working Environment | Dielectric strength | 1500VAC,1minute | ||
Noise (1m) | ≤50dB | |||
Ambient temperature | -10℃~+50℃ | |||
Humidity | 0~90%, No condensation | |||
Altitude | <3000m | |||
Higher than 3000m rated power should be reduced | ||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Size | 610*950*1300 mm | |||
Weight | 210 Kg |
Project Sample
EEDNB 20KW Off-Grid Power Frequency Inverter Single phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
Model | EEDNB20-96 | EEDNB20-110 | EEDNB20-220 | |
DC input | Input rated voltage | 96 VDC | 110 VDC | 220 VDC |
Input rated current | 208 A | 182 A | 91 A | |
Input DC voltage allowing range | 75-135 VDC | 80-145 VDC | 180-300 VDC | |
AC Bypass | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | ||
Input rated current | 182A / 167A / 91 A / 83A | |||
Bypass transfer time | ≤4 ms | |||
AC output | Output rated power | 16KW | ||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
Output rated current | 182A / 167A / 91 A / 83A | |||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | |||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |||
Wave | Pure sine wave (Isolation transformer) | |||
THD. | ≤3%(Linear load) | |||
Power factor (PF) | 0.8 | |||
Overload capacity | 120%,3 minutes,150%,10 second | |||
Crest factor (CF) | 3:01 | |||
Inverter efficiency | >90% | |||
Working Environment | Dielectric strength | 1500VAC,1minute | ||
Noise (1m) | ≤50dB | |||
Ambient temperature | -10℃~+50℃ | |||
Humidity | 0~90%, No condensation | |||
Altitude | <3000m | |||
Higher than 3000m rated power should be reduced | ||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Size | 610*950*1300 mm | |||
Weight | 210 Kg |