EEDNB 20KW
ENGELEC
EEDNB 20KW
| Availability: | |
|---|---|
EEDNB 20KW Off-Grid Power Frequency Inverter Single phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
| Model | EEDNB20-96 | EEDNB20-110 | EEDNB20-220 | |
| DC input | Input rated voltage | 96 VDC | 110 VDC | 220 VDC |
| Input rated current | 208 A | 182 A | 91 A | |
| Input DC voltage allowing range | 75-135 VDC | 80-145 VDC | 180-300 VDC | |
| AC Bypass | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | ||
| Input rated current | 182A / 167A / 91 A / 83A | |||
| Bypass transfer time | ≤4 ms | |||
| AC output | Output rated power | 16KW | ||
| Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
| Output rated current | 182A / 167A / 91 A / 83A | |||
| Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | |||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |||
| Wave | Pure sine wave (Isolation transformer) | |||
| THD. | ≤3%(Linear load) | |||
| Power factor (PF) | 0.8 | |||
| Overload capacity | 120%,3 minutes,150%,10 second | |||
| Crest factor (CF) | 3:01 | |||
| Inverter efficiency | >90% | |||
| Working Environment | Dielectric strength | 1500VAC,1minute | ||
| Noise (1m) | ≤50dB | |||
| Ambient temperature | -10℃~+50℃ | |||
| Humidity | 0~90%, No condensation | |||
| Altitude | <3000m | |||
| Higher than 3000m rated power should be reduced | ||||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
| Size | 610*950*1300 mm | |||
| Weight | 210 Kg | |||
Project Sample
EEDNB 20KW Off-Grid Power Frequency Inverter Single phase
Features
◆ Complete isolation-type inverter technology, noiseless output.
◆ Adoption of advanced SPWM technology, pure sine wave output.
◆ Dynamic current loop control technology to ensure inverter reliable operation.
◆ Wide DC input voltage range.
◆ Excellent EMC design.
◆ Low output harmonic distortion (THD≤3%).
◆ LED indicators for input voltage range, load power range, normal output & failure state.
◆ Optional energy saving mode.
◆ Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage over-temperature, and inverter’s inner fault identification protections.
◆ Wide working temperature range (industrial level).
◆ Continuous operation at full power.
Application:
◆ For desolate area like mountain, island, pasturing area, etc.
◆ For transportation system like beacon light, traffic light, street light, etc.
◆ For communication system: unattached operation microwave middle station, optical cable maintenance station, etc.
◆ For solar power station, wind-solar power station, park charging station, family power house, factory power station, etc.
◆ For solar building: has good business future.
◆ For the new technology application project.
Technical Parameters
| Model | EEDNB20-96 | EEDNB20-110 | EEDNB20-220 | |
| DC input | Input rated voltage | 96 VDC | 110 VDC | 220 VDC |
| Input rated current | 208 A | 182 A | 91 A | |
| Input DC voltage allowing range | 75-135 VDC | 80-145 VDC | 180-300 VDC | |
| AC Bypass | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | ||
| Input rated current | 182A / 167A / 91 A / 83A | |||
| Bypass transfer time | ≤4 ms | |||
| AC output | Output rated power | 16KW | ||
| Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
| Output rated current | 182A / 167A / 91 A / 83A | |||
| Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | |||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |||
| Wave | Pure sine wave (Isolation transformer) | |||
| THD. | ≤3%(Linear load) | |||
| Power factor (PF) | 0.8 | |||
| Overload capacity | 120%,3 minutes,150%,10 second | |||
| Crest factor (CF) | 3:01 | |||
| Inverter efficiency | >90% | |||
| Working Environment | Dielectric strength | 1500VAC,1minute | ||
| Noise (1m) | ≤50dB | |||
| Ambient temperature | -10℃~+50℃ | |||
| Humidity | 0~90%, No condensation | |||
| Altitude | <3000m | |||
| Higher than 3000m rated power should be reduced | ||||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
| Size | 610*950*1300 mm | |||
| Weight | 210 Kg | |||
Project Sample