Features
◆ The product can be manufactured in accordance with either JB/T6939.1-2004 industrial standard, GB/T 19115.1-2003 national standard or users’ technical requirements.
◆ EEA1 controllers adopt three-phase dump load control.
◆ The total power of three-phase dump load is 200% larger than the rated power of the wind turbine. Ensure safe operation of the overall wind turbine system.
◆ When the batteries group damaged or be disjointed, the three-phase dump load will automatically start to avoid the idle run of the wind turbine and the occurrence of runaway accident.
◆ It has reverse connection, anti-decoupling and damage-resisting protection of the battery.
◆ Over-charging protection of the battery: When the battery is full (the battery pressure reaching 125% of the rated pressure), the controller will automatically carry out three-phase dump load to stop charging the battery.
◆ Auto recovery of battery charging: When the battery pressure reduces to 108% of the rated pressure, the dump load will stop three-phase dump load to automatically recover battery charging.
◆ For the different wind turbine type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
◆ The controller is equipped with manual three-phase dump load switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.
Technical Parameters
| Type | 750W-24Vdc |
| Wind turbine rated power | 750W |
| Wind turbine max. power | 1.5KW |
| Solar panel power | 200W |
| Battery | 24Vdc |
| Function | Rectifier,charge, control |
| Wind turbine 3-phase dump load voltage | 29±1Vdc |
| Wind turbine 3-phase brake voltage | 30±1Vdc |
| Wind turbine Recovery charging voltage | 27±1Vdc |
| Solar controller stop charging voltage | 30±1Vdc |
| Solar restore charge voltage | 27±1Vdc |
| Low-voltage of the battery | 20±1Vdc |
| Self-provided connecting wire of the battery | >6mm² |
| Work environment temperature | -30-60°C |
| Relative humidity | <90% No condensation |
| Noise (1m) | <40dB |
| Degree of protection | IP20(Indoor) |
| Cooling method | Forced air cooling |
| Size of the controller (mm) | 450*360*270mm |
| Weight of the controller | 9kg |
| Size of the dump load (mm) | 360*300*270mm |
| Weight of the dump load | 5kg |
Project Sample
EEA1 750W Wind/Solar Hybrid Controller Off-grid
Features
◆ The product can be manufactured in accordance with either JB/T6939.1-2004 industrial standard, GB/T 19115.1-2003 national standard or users’ technical requirements.
◆ EEA1 controllers adopt three-phase dump load control.
◆ The total power of three-phase dump load is 200% larger than the rated power of the wind turbine. Ensure safe operation of the overall wind turbine system.
◆ When the batteries group damaged or be disjointed, the three-phase dump load will automatically start to avoid the idle run of the wind turbine and the occurrence of runaway accident.
◆ It has reverse connection, anti-decoupling and damage-resisting protection of the battery.
◆ Over-charging protection of the battery: When the battery is full (the battery pressure reaching 125% of the rated pressure), the controller will automatically carry out three-phase dump load to stop charging the battery.
◆ Auto recovery of battery charging: When the battery pressure reduces to 108% of the rated pressure, the dump load will stop three-phase dump load to automatically recover battery charging.
◆ For the different wind turbine type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
◆ The controller is equipped with manual three-phase dump load switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.
Technical Parameters
| Type | 750W-24Vdc |
| Wind turbine rated power | 750W |
| Wind turbine max. power | 1.5KW |
| Solar panel power | 200W |
| Battery | 24Vdc |
| Function | Rectifier,charge, control |
| Wind turbine 3-phase dump load voltage | 29±1Vdc |
| Wind turbine 3-phase brake voltage | 30±1Vdc |
| Wind turbine Recovery charging voltage | 27±1Vdc |
| Solar controller stop charging voltage | 30±1Vdc |
| Solar restore charge voltage | 27±1Vdc |
| Low-voltage of the battery | 20±1Vdc |
| Self-provided connecting wire of the battery | >6mm² |
| Work environment temperature | -30-60°C |
| Relative humidity | <90% No condensation |
| Noise (1m) | <40dB |
| Degree of protection | IP20(Indoor) |
| Cooling method | Forced air cooling |
| Size of the controller (mm) | 450*360*270mm |
| Weight of the controller | 9kg |
| Size of the dump load (mm) | 360*300*270mm |
| Weight of the dump load | 5kg |
Project Sample